AR

Carpe Pulse

PLS-2026-DOM498F

DOMINICK'S STEAKHOUSE LLC · Hospitality · Delivered

Survey Queue
Order Request — from Minerva Reasoning Engine
AW
Ordered by Ada Whitfield(via e2e-test-uw)
Role: Underwriter
Submission 14b46927-b4d5-4971-a380-0703aa9eca0f · Carpe ID 57e7ddd4229f92a5
Ordered
Jun 19, 2026, 11:24 PM UTC
Pulse Request ID
PLS-2026-684945
Why — Areas of Interest (what needs attention)
No specific focus items on the order — full-scope survey.
Subject of the Order
Business nameDominick's Steakhouse LLC
Address15169 N Scottsdale Rd · Scottsdale, AZ · 85254
Source of record: pulse_survey_requests · verbatim payload retained for audit Received · HMAC verified
DOMINICK'S STEAKHOUSE LLC
15169 N SCOTTSDALE RD, SCOTTSDALE , AZ 85254 · Job PLS-2026-DOM498F
0
Photos
0
Intake
0
AI reads
Average
Risk grade
Reference

Property Profile (COPE)

Pulse capturedInspector documented
Construction typeMasonry Non-Combustible (ISO Class 4)
Year built2008
Stories1 plus elevated mezzanine
Units in building4 (multi-unit retail center)
Insured premises8,000 sqft
Total building24,500 sqft
Roof typeModified Bitumen
Roof age7 years (replaced 2019)
OccupancyFine-dining restaurant with full bar, raw seafood, live entertainment, valet, and private dining
NAICS722511 Full-Service Restaurants
Cooking hazardHigh open-flame broiler, charcoal grill, deep frying
SprinkleredYes, full coverage wet system
Hood suppressionAnsul R-102 wet chemical (UL-300)
Public Protection ClassPPC 02
Business operations

Dominick's Steakhouse operates as a single-unit, fine-dining restaurant in a four-unit commercial building on N Scottsdale Road. The concept includes a full bar, raw-bar service with oysters and crudo, an elevated mezzanine private dining room, valet service at the front porte-cochere, and live entertainment on Friday and Saturday evenings.

Reference

Food Safety, Prep and Holding

Pulse capturedInspector documented
Items reviewed7
Prior health-inspection follow-up

A May 2026 Maricopa County visit cited a cold-hold log gap at the raw bar. Current reach-in and walk-in temperatures were in range during the survey, but the raw-bar log issue recurred on July 19 and is tracked in the Raw Seafood section.

Control
ResponseDetail
Cold-hold temperatures at reach-ins and walk-insPassAll eight prep-line reach-ins and both walk-in coolers read at or below 40 F.
Hot-hold at soup wells and au-jus stationPassHot wells read 142 F to 148 F. Probe verification matched posted log entries.
Internal cook temperature, beef and poultryPassSous chef demonstrated probe reads and probe sanitization between checks.
Sanitizer concentrationMinor NoteTwo of six wiping buckets were under 150 ppm and were re-charged during the walk.
Dishmachine final-rinse temperaturePassDoor-type dishmachine final rinse read 184 F on three consecutive cycles.
Reference

Raw Seafood Handling and Slip / Trip / Fall

Pulse capturedInspector documentedInspector interviewed
Raw seafood items reviewed5
Slip / trip / fall items reviewed6
Raw Seafood Control
ResponseDetail
Raw-bar cold-hold log continuityCorrectionLog shows a 9-hour gap on July 19 after a heavy banquet service. Current cold-hold reads were 34 F to 36 F.
Oyster and crudo sourcing tagsPassFDA shellstock tags retained on file with current rotation and 90-day archive.
Consumer advisory on menuPassRequired undercooked-product advisory confirmed with the GM.
Slip / Trip / Fall Control
ResponseDetail
Kitchen floor condition and slip-resistancePassQuarry tile sound; anti-slip mats in good condition at fryer and broiler stations.
Mezzanine stair, handrail and nosingPassOpen stair has compliant handrails on both sides and intact non-slip nosing.
Parking lot and valet path conditionMinor NoteAsphalt and striping are in good repair; one pole-mounted lamp is out near valet drop-off.
Reference

Fire and Life Safety

Pulse capturedInspector documented
Items reviewed9
Control
ResponseDetail
Hood and duct system, last cleaning tagPassTag dated May 6, 2026. NFPA 96 quarterly cleaning schedule is appropriate for exposure.
Ansul UL-300 hood suppression service currencyCriticalPosted tag dated November 12, 2025. Semi-annual service interval lapsed by roughly three months.
Portable fire extinguishersPassEight ABC and two Class K units; tags current and gauges in the green.
Mezzanine private dining room rear egressCorrectionRear egress door was blocked by a stacked banquet equipment cart at the start of the walk. Cart relocated during the survey.
Central station fire alarm functional testPassLast test February 18, 2026, passed. Certificate photographed.
Reference

Alcohol Service, Valet, Entertainment and Events

Pulse capturedInspector documentedInspector interviewed
Alcohol service items reviewed7
Valet / entertainment items reviewed5
Control
ResponseDetail
On-premise liquor license posted and currentPassArizona Series 12 license posted at the bar, current through March 2027.
TIPS / Title 4 certificationPass14 of 14 service-floor staff hold current Arizona Title 4 cards.
Refusal-of-service and incident logPassBound log maintained at manager station; four entries in prior 60 days.
Valet stand controls and key managementPassLocked key board and numbered hooks; tickets matched against drop-off log.
ASCAP / BMI music licensingPassGM confirmed current accounts; certificates retained at corporate office.
Reference

Employee Practices and Lock-Out / Tag-Out

Pulse capturedInspector documentedInspector interviewed
Employee practice items reviewed4
LOTO items reviewed7
Control
ResponseDetail
Food handler certificates on filePassAll BOH staff hold current Maricopa County food handler cards.
Allergen handling protocolPassGM and executive chef described POS allergen flag, dedicated saute pan, and FOH callout to expo.
First-aid kit and burn-care signageMinor NoteTwo kits present and stocked; no posted location signage in the service alley.
Walk-in cooler compressor disconnect labelingCorrectionDisconnect is unlabeled. Inspector confirmed correct unit by tracing conduit run.
Slicer plug-lockout deviceCorrectionSlicer plug-lockout sleeve is missing from the prep station.
Reference

Consolidated Action Items

Pulse capturedInspector documentedInspector interviewed
Critical finding1
Corrections required4
Minor notes4
Carrier follow-up

Critical and Correction items should be tracked to closure. Minor Notes are noteworthy operational improvements but do not require carrier follow-up unless the account fails to address repeat conditions.

Pending

Probable Maximum Loss (PML)

Fire
PerilFire
LikelihoodAverage
Calc methodEngineering Judgment PML Method
Building PML %35%
Building PML $980,000 USD
BI PML $675,000 USD
Scenario

A hood suppression failure during broiler operations allows fire to extend into the hood and duct before manual extinguisher response and sprinkler control. Loss is bounded by non-combustible construction, full sprinkler coverage, central station fire alarm, and Scottsdale Fire Department proximity.

Operations
No operations detail recorded for this survey yet.
Financial / Loss
Valuation and loss analysis are pending carrier-supplied data.
AI· Opus 4.8

AI Loss-Control Assessment

No AI assessment has been run on the captured media yet.
Recommendations
26-1Ansul R-102 hood suppression service overdue on broiler lineCritical · New

Engage Pacific Fire Equipment Co. to complete semi-annual service on the Ansul R-102 wet-chemical system covering the open-flame broiler, charcoal grill, and salamander. Furnish the updated service tag to the carrier.

26-2Raw-bar cold-hold log gap on July 19Important · New

Re-train raw-bar attendants on shift-handoff cold-hold logging. Add a posted check at open and close so temperature-log continuity does not depend on verbal handoff after banquet events.

26-3Mezzanine private dining rear egress blocked at start of walkImportant · New

Add a daily storage-clearance check to the opening and closing checklist for the mezzanine private dining room. Banquet carts and equipment must not be staged in the rear egress path.

26-4Walk-in cooler compressor disconnect unlabeledImportant · New

Apply a permanent equipment label identifying the controlled walk-in cooler unit at the compressor disconnect.

26-5Slicer plug-lockout device missingImportant · New

Replace the plug-lockout sleeve, store it at the slicer, and brief the prep team on required use outside the cord-and-plug exclusive-control exception.